Contents
StandardISO

ISO 16750-2

Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 2: Electrical loads

ISO 16750-2 defines electrical supply stresses and tests used to check whether vehicle electronics can withstand conditions such as voltage drops, overvoltage and reversed connections.

What it is

ISO 16750-2 is the electrical-load part of ISO’s environmental testing series for road-vehicle electrical and electronic equipment. It provides a basis for specifying how equipment must respond when its electrical connections experience demanding conditions.

For a beginner, the key idea is that a vehicle supply is not a perfectly steady laboratory power source. Electronics must tolerate disturbances and recover in an agreed way. This is a paid engineering standard; using it requires the actual document and the project’s applicable requirements.

Who it applies to

It concerns teams developing and validating vehicle electrical and electronic systems and components, including ECUs, smart sensors, actuators and power-distribution equipment. Its scope excludes motorcycles and mopeds.

Hardware engineers usually lead its application, with system architects, software engineers and validation teams agreeing the required behavior. It is not automatically a legal obligation for every product: applicability commonly comes through customer specifications, contracts or internal engineering requirements.

For a smart LIN node, distinguish requirements on the finished assembly from the capabilities of its individual chips. A semiconductor qualification or a protected transceiver alone does not establish that the assembled node meets its electrical-load requirements.

What it covers

The document addresses supply-voltage conditions, interruptions, connection faults and electrical protection or insulation checks. Its contents include load-dump testing, which concerns a supply overvoltage associated with a sudden loss of electrical load.

Electrical condition Practical engineering concern
Supply variation or interruption Regulator behavior, resets and recovery
Overvoltage or reversed supply Input protection and component stress
Ground or supply offset Voltage differences between connected circuits
Open circuits, shorts and overloads Protection behavior and fault containment
Insulation checks Unwanted current paths and electrical separation

Do not reduce compliance to “the ECU survived.” The test specification must also establish what functions may degrade, what must remain available and how recovery is assessed. Applicable tests, operating conditions and acceptance criteria need to be selected from the standard and the customer requirements.

How it fits with other documents

ISO 16750-1 provides the general framework for the series. Other parts address environmental stresses such as mechanical and climatic loads; electrical-load testing does not replace those assessments.

Electromagnetic compatibility is outside this document’s scope. Coordinate the electrical-load plan with the project’s separate EMC requirements so that neither team assumes the other has covered a disturbance.

Functional-safety requirements add another layer: passing environmental tests does not by itself establish that a system is safe. Customer specifications may also impose additional conditions or different acceptance criteria, which must be resolved explicitly.

In practice

Start by recording the equipment’s supply interfaces, grounding, operating modes and expected vehicle installation. Agree which functions must operate through each disturbance and which may reset or temporarily stop.

Use these decisions to select protection devices, regulators, supervision circuits and software recovery behavior. For an eFuse, examine both its own robustness and the supply disturbance its switching can create for downstream equipment.

During testing, observe functional behavior alongside electrical measurements. Check restart sequences, communication recovery, diagnostic records and persistent data where relevant. Keep the tested configuration, deviations and results traceable to the requirements so later hardware or software changes can be assessed.

What it means for your discipline

  • Hardware & siliconCore

    Translate electrical stresses into power-input protection, regulator, insulation and component requirements. Own the hardware test plan and evidence that the equipment meets the agreed acceptance criteria.

  • E/E architecturePartial

    Define supply boundaries, grounding and power-distribution assumptions so component tests represent the vehicle installation. Coordinate expected behavior during supply disturbances across connected ECUs.

  • Functional safetyPartial

    Assess whether supply disturbances can violate safety requirements and specify the necessary fault response. Use electrical-load test results as supporting evidence within the wider safety argument.

  • Base softwarePartial

    Implement voltage supervision, reset handling and recovery behavior consistent with the hardware capabilities. Check that communication and stored data behave as required during disturbed power.

  • Diagnostics & lifecyclePartial

    Define how supply faults are detected, recorded and cleared. Distinguish the initiating electrical disturbance from secondary faults caused by resets or unavailable ECUs.

No direct stake: Cybersecurity · HPC & application software · Networks & communication · Software update & OTA